An upblast roof exhaust fan is the fan most Saudi commercial kitchens use to pull smoke, heat and grease-laden air out of the cooking hood and throw it straight up, away from the roof. This guide explains how upblast fans work, how to work out the airflow your hood needs, and how to choose between the sizes in our RCU upblast range. It is written by the AMH-CO team, who have supplied and installed kitchen exhaust and ANSUL fire suppression systems in Saudi Arabia since 2007.
What is an upblast roof exhaust fan?
An upblast fan is a centrifugal fan mounted on a curb at the top of the exhaust duct. The motor sits outside the airstream, and the air leaves the fan vertically through the top of the housing. Because the discharge points upwards, grease and hot air are carried away from the roof surface instead of being blown across it, which protects the roof and keeps the area around the fan cleaner.
Our RCU series has a cast aluminium alloy body and is available in direct drive and belt drive versions. According to the manufacturer data, the standard configuration works in ambient temperatures up to 320°F (160°C), and an upgraded configuration can reach 572°F (300°C), which is why the series is also offered for smoke exhaust duty.
According to the manufacturer’s catalogue, the housing is laser-cut aluminium alloy with a one-piece drawn base. Belt-drive models are designated RCU and direct-drive models RDU. The impeller is laser-cut, die-formed and balanced to grade G4.0 of ISO 1940, and can be supplied in aluminium alloy, carbon steel or stainless steel. The drive cover opens by hand for routine cleaning, and an explosion-proof version is available.
Where upblast fans are used
- Commercial kitchen hoods in restaurants, hotels, central kitchens, hospitals and catering facilities.
- Commercial laundries and other rooms that produce heat and moisture.
- General roof exhaust for workshops, plant rooms and storage areas.
- Smoke exhaust, when the higher-temperature configuration is specified.
How to size an upblast fan in four steps
1. Work out the airflow your hood needs (CFM)
If your hood is a listed (tested) hood, use the exhaust rate given by the hood manufacturer. For a simple canopy hood without a listing, designers often follow the approach in the International Mechanical Code, which sets a minimum exhaust rate per linear foot of hood depending on the cooking duty. For a wall-mounted canopy the values are 200 CFM per foot for light duty (ovens, steamers), 300 for medium duty (fryers, griddles), 400 for heavy duty (charbroilers, woks) and 550 for extra-heavy duty (solid-fuel cooking). Island hoods need more air than wall hoods.
Example: a 3 m (about 10 ft) wall canopy over fryers and griddles needs around 10 × 300 = 3,000 CFM.
The fan catalogue also gives a quick method based on hood area, for use where local codes do not specify a rate: about 50 CFM per square foot of hood for light duty (ovens, ranges, kettles), 75 for medium duty (fryers, griddles) and 100 for heavy duty (charbroilers, electric broilers). Some local codes require 100 CFM per square foot for wall-style hoods.
2. Estimate the static pressure of the duct system
Every grease filter, bend, metre of duct and any ecology unit adds resistance (static pressure). The catalogue airflow of a fan is measured with little or no resistance, so the real airflow on site is always lower. Long duct runs, many bends or extra filtration mean you need a larger fan, or a utility (centrifugal) fan, which handles higher pressure.
As a guide, the catalogue puts the typical static pressure of a kitchen exhaust system in a one-storey building at about 155 to 250 Pa, and recommends a utility blower when the exhaust has to be pulled through long duct runs, typically three storeys or more.
3. Choose a size with a safety margin
Pick the model whose airflow at your expected static pressure covers the hood requirement. In the example above, an RCU10 (3,000 CFM nominal) would be at its limit, so an RCU14 (4,800 CFM nominal) is the safer choice if the ductwork is long. Ask us for the fan curve of the model you are considering; we will check it against your hood and duct layout.
4. Plan make-up air
Every cubic metre of air you exhaust has to be replaced. Without make-up air, doors become hard to open, the hood stops capturing smoke properly and gas appliances may burn poorly. Most kitchens pair the exhaust fan with a fresh air (supply) fan sized to replace most of the exhausted air. The fan catalogue recommends supplying 80% of the exhaust airflow; the remaining 20% is drawn from the areas next to the kitchen, which keeps cooking smells out of the dining room. Our fresh air fan guide explains how to size it.
RCU upblast fan sizes and specifications
| Model | Size | Airflow (CFM) | Airflow (m³/h) | Motor |
|---|---|---|---|---|
| RCU5 | Size 5 | On request | On request | 0.25 HP |
| RCU8 | Size 8 | 2,500 | ≈ 4,250 | 0.5 HP |
| RCU10 | Size 10 | 3,000 | ≈ 5,100 | 1 HP |
| RCU14 | Size 14 | 4,800 | ≈ 8,160 | 1.5 HP |
| RCU16 | Size 16 | 5,800 | ≈ 9,850 | 2 HP |
| RCU18 (1.5 HP) | Size 18 | 6,200 | ≈ 10,530 | 1.5 HP |
| RCU18 (2 HP) | Size 18 | 8,100 | ≈ 13,760 | 2 HP |
| RCU20 | Size 20 | 8,300 | ≈ 14,100 | 2 HP |
| RCU24 | Size 24 | 11,600 | ≈ 19,710 | 3 HP |
| RCU28 | Size 28 | 14,000 | ≈ 23,790 | 5.5 HP |
| RCU32 | Size 32 | 17,000 | ≈ 28,880 | 7.5 HP |
There are two size 18 models: the 1.5 HP version (6,200 CFM) and the 2 HP version (8,100 CFM). The 2 HP model moves noticeably more air and suits longer ducts or heavier cooking lines.
Footprint and height
| Models | Footprint (mm) | Height (mm) |
|---|---|---|
| RCU10 / RCU14 | 630 × 630 | 725 |
| RCU16 / RCU18 | 712 × 712 | 925 |
| RCU20 / RCU24 | 838 × 838 | 1,130 |
| RCU28 / RCU32 | 1,016 × 1,016 | 1,283 |
Upblast, utility or inline: which fan do you need?
- Upblast roof fan: the usual choice when the duct ends on the roof and the duct run is reasonably short. Simple to install on a roof curb and easy to service.
- Utility (centrifugal) fan: better when the system has high resistance, such as long ducts, many bends, or an ecology unit for smoke and odour control. It can be installed on the roof or at ground level. See our utility fan guide.
- Square inline fan: a centrifugal fan with a backward-curved aluminium impeller, installed inside the duct run, on the floor or hung from the ceiling on neoprene or spring isolators, where there is no roof access. A side-discharge arrangement reduces losses at corners, and the catalogue advises a straight duct of about two to three wheel diameters after the fan to reach its rated performance.
Roof clearances
The fan catalogue lists the NFPA minimum distances for restaurant exhaust and supply fans:
- Roof deck to the top of the exhaust fan windband: at least 1,016 mm.
- Roof deck to the top of the curb: at least 457 mm.
- Supply (fresh air) fan intake: at least 3 m from all exhaust fans. Where that is not possible, the vertical separation between exhaust and supply must be at least 914 mm.
Accessories such as a grease collector and a hinge kit, which lets the fan tilt open for cleaning, make maintenance of kitchen exhaust fans much easier.
Installation and maintenance tips
- Mount the fan on a level, weather-tight roof curb, with enough clearance around it for service access.
- Keep grease out of the roof: check the grease drain and collection point regularly.
- On belt drive models, check belt tension and wear at every service visit.
- Clean the fan wheel and housing as part of the kitchen exhaust cleaning programme. The frequency depends on how much you cook; busy kitchens need it more often.
- Make sure the exhaust system works together with your ANSUL R-102 fire suppression system as the design requires.
Frequently asked questions
What size upblast fan do I need for my kitchen?
Start from the hood exhaust rate (hood length × the rate for your cooking duty), then allow for duct resistance. As a rough guide, small hoods often need a size 8–10, medium kitchens a size 14–18 and large cooking lines a size 20 or above. Send us your hood length and duct layout and we will recommend a model.
Can upblast fans handle hot exhaust air?
Yes. According to the manufacturer data, the standard RCU configuration works up to 320°F (160°C), and the upgraded configuration up to 572°F (300°C).
Are the fans direct drive or belt drive?
The RCU series is available in both. Direct drive has fewer parts to maintain; belt drive allows the fan speed to be adjusted by changing the pulleys.
Do you install upblast fans outside Makkah?
Yes. We supply across Saudi Arabia and serve customers in Makkah, Jeddah and Riyadh, among other cities.
Get a recommendation
Call or WhatsApp us on 0571535353, email info@amh-co.com or use our contact page. Tell us the hood length, the type of cooking and the duct route, and we will suggest the right fan size.